![]() Spiral CT Protocols
|
|
Neuro Circle of Willis: Detection and assessment of intracranial aneurysm |
|
Specific Anatomic Region |
Circle of Willis |
|
|
Application |
Detection and assessment of intracranial aneurysm |
|
|
Author |
Liang EY et al. |
|
|
Reference Source |
AJR 1995; 165:1497-1502 |
|
|
Scanner Used |
GE HiSpeed Advantage |
|
|
Injection Rate |
3ml/sec |
|
|
Contrast Volume and Type |
135ml of Ioxphol 300 |
|
|
Area Scanned |
From floor of sella through mid brain |
|
|
Scan Delay |
20sec |
|
|
Length of Spiral (time) |
35sec |
|
|
Slice Thickness |
1mm |
|
|
Table Speed/Pitch |
1mm/sec |
|
|
Reconstruction Interval |
1mm |
|
|
3D Technique Used |
Shaded-surface display |
|
|
Comment: The authors in this article stress the value of 3D imaging for the evaluation of aneurysms. |
||