Liver transplant evaluation (donor)
| Specific Anatomic Region | Liver | |
| Application | Liver transplant evaluation (donor) | |
| Author | Fishman EK | |
| Reference Source | Personal Communication | |
| Scanner Used | Siemens Plus4 Volume Zoom | |
| KV / mAs / Time per Rotation (sec) | 120 / 150 / .5 | |
| Detector Collimation (mm) | 1 | |
| Slice Thickness (mm) | 1.25 | |
| Data Reconstruction Interval (mm) | 1 mm and 1 and 5 mm (venous phase only) | |
| Table Speed (mm per rotation) / Pitch | 6 / 6 | |
| Oral Contrast | 750 cc of water | |
| IV Contrast Volume and Type | 120-150 cc of Omnipaque 350 | |
| Injection Rate | 3 cc / sec | |
| Scan Delay (sec) | 25 / 50-60 sec | |
| 3D Technique Used | Volume rendering | |
| Comment: -This protocol is for the patient who is a liver donor. We obtain a set of venous phase images at 5 mm intervals to do volumetrics. Typically in adult to adult transplants, we do right lobe volume, and in adult to child transplants, we do lateral left lobe volumes. | ||