Eval hepatic a. anatomy for liver transplant (recipient)
| Specific Anatomic Region | Liver | |
| Application | Evaluate hepatic arterial anatomy for liver transplant (recipient) | |
| Author | Fishman EK | |
| Reference Source | Personal Communication | |
| Scanner Used | Siemens Plus4 Volume Zoom | |
| KV / mAs / Time per Rotation (sec) | 120 / 125 / .5 | |
| Detector Collimation (mm) | 1 | |
| Slice Thickness (mm) | 1.25 | |
| Data Reconstruction Interval (mm) | 1 | |
| Table Speed (mm per rotation) / Pitch | 6 / 6 | |
| Oral Contrast | 750 cc of water | |
| IV Contrast Volume and Type | 120 cc of Omnipaque 350 | |
| Injection Rate | 3 cc / sec | |
| Scan Delay (sec) | 25-30 sec (arterial) / 50-60 sec (venous) | |
| 3D Technique Used | Volume rendering | |
| Comment: -Dual phase imaging is used to exclude an occult hepatoma as well as to create a vascular map. | ||