Cervical spine: Trauma-extent of injury
| Specific Anatomic Region | Cervical spine | |
| Application | Trauma-extent of injury | |
| Author | Fishman EK | |
| Reference Source | Personal Communication | |
| Scanner Used | Siemens Plus4 Volume Zoom | |
| KV / mAs / Time per Rotation (sec) | 140 / 200 / 1 | |
| Detector Collimation (mm) | 1 | |
| Slice Thickness (mm) | 1.25 | |
| Data Reconstruction Interval (mm) | 1 | |
| Table Speed (mm per rotation) / Pitch | 3 / 3 | |
| Oral Contrast | N/A | |
| IV Contrast Volume and Type | N/A | |
| Injection Rate | N/A | |
| Scan Delay (sec) | N/A | |
| 3D Technique Used | MPR and Volume rendering (as needed) | |
| Comment: -This is a detailed exam, and not a screening study to replace plain x-rays. Usually either plain film findings, or the mode of injury dictate this exam. | ||