Bladder injury
| Specific Anatomic Region | Bladder | |
| Application | Bladder injury (CT cystography) | |
| Author | Fishman EK | |
| Reference Source | Personal Communication | |
| Scanner Used | Siemens Plus4 Volume Zoom | |
| KV / mAs / Time per Rotation (sec) | 120 / 165 / .5 | |
| Detector Collimation (mm) | 4 x 2.5 | |
| Slice Thickness (mm) | 3 | |
| Data Reconstruction Interval (mm) | 2-5 | |
| Table Speed (mm per rotation) / Pitch | 12.5 / 5 | |
| Oral Contrast | N/A | |
| Contrast Volume and Type | Up to 400 cc of dilute contrast (5% Omnipaque) | |
| Injection Rate | Dripped in under gravity | |
| Scan Delay (sec) | N/A | |
| 3D Technique Used | Volume rendering if needed | |
| Comment: -Contrast is dripped in under gravity up to 400 cc or less if the patient experiences pain. Please make sure the Foley catheter is clamped. | ||