![]() Spiral CT Protocols
|
|
Kidney Suspected renal mass |
|
Specific Anatomic Region |
Kidney |
|
|
Application |
Suspected renal mass |
|
|
Author |
Fishman EK, Urban, BA |
|
|
Reference Source |
Spiral CT Evaluation of the Kidney (in: Spiral CT: Principles, Techniques and Clinical Applications. Fishman, Jeffrey, eds. 1998) |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
3cc/sec |
|
|
Contrast Volume and Type |
120cc Omnipaque 350 |
|
|
Area Scanned |
From 2cm above to 2cm below kidneys |
|
|
Scan Delay (2 delays if dual spiral) |
30sec/70 sec (dual spiral) |
|
|
Length of Spiral (time) |
30-40sec each |
|
|
Slice Thickness |
3-5mm |
|
|
Table Speed/Pitch |
3-5mm |
|
|
Reconstruction Interval |
2-3mm |
|
|
3D Technique Used |
Volume rendering |
|
|
Comment: A few noncontrast scans (5mm) are obtained prior to injecting contrast. The key to an accurate evaluation of a renal mass is imaging in several different phases to look at the enhancement pattern and lesion borders. |
||