![]() Spiral CT Protocols
|
|
Chest Solitary node eval |
|
Specific Anatomic Region |
Chest |
|
|
Application |
Solitary pulmonary nodule evaluation |
|
|
Author |
Fishman EK |
|
|
Reference Source |
Personal communication |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
See note in Comment |
|
|
Contrast Volume and Type |
N/A |
|
|
Area Scanned |
Several mm above and below nodule |
|
|
Scan Delay |
None |
|
|
Length of Spiral (time) |
Usually 10sec |
|
|
Slice Thickness |
2-3mm |
|
|
Table Speed/Pitch |
2-3mm/sec or a pitch of 1 |
|
|
Reconstruction Interval |
1mm |
|
|
3D Technique Used |
None usually needed |
|
|
Comment: The study looks for the presence of fat or calcification within a lesion in order to declare it benign. Recent work with enhancement of nodules may prove valuable in the future. Standard algorithm is used without edge enhancement. |
||