Specific Anatomic Region |
Common bile duct |
|
Application |
Detection of choledocholithiasis |
|
Author |
Fishman EK |
|
Reference Source |
Personal Communication |
|
Scanner Used |
Siemens Plus4 Volume Zoom |
|
KV / mAs / Time per Rotation (sec) |
120 / 165 / .5 |
|
Detector Collimation (mm) |
2.5 |
|
Slice Thickness (mm) |
3 |
|
Data Reconstruction Interval (mm) |
1-2 |
|
Table Speed (mm per rotation) / Pitch |
12.5 / 5 |
|
Oral Contrast |
750 cc of water |
|
IV Contrast Volume and Type |
N/A
|
|
Injection Rate |
N/A |
|
Scan Delay (sec) |
N/A |
|
3D Technique Used |
N/A |
|
Comment: -This protocol is a very focused exam. Some articles have suggested using a biliary contrast agent, and then generate 3D images of the biliary tree. |