Specific Anatomic Region |
Hepatic Vascular Tree |
|
Application |
Create a vascular map for preoperative evaluation of the liver. (dual phase study) |
|
Author |
Fishman EK |
|
Reference Source |
Personal Communication |
|
Scanner Used |
Siemens Plus4 Volume Zoom |
|
KV / mAs / Time per Rotation (sec) |
120 / 125 / .5 |
|
Detector Collimation (mm) |
1 |
|
Slice Thickness (mm) |
1.25 |
|
Data Reconstruction Interval (mm) |
1 |
|
Table Speed (mm per rotation) / Pitch |
6 / 6 |
|
Oral Contrast |
750 cc of water |
|
IV Contrast Volume and Type |
120-150 cc of Omnipaque 350
|
|
Injection Rate |
3 cc / sec |
|
Scan Delay (sec) |
25-30 / 60 |
|
3D Technique Used |
Volume rendering/MIP |
|
Comment: -This protocol is a dual phase study that focuses on creating a detailed vascular map. Volume rendering is best for the arterial and venous mapping, but MIP helps with the hepatic veins on the venous phase. |