Specific Anatomic Region |
Kidney |
|
Application |
R/O renal or ureteral calculus
|
|
Author |
Fishman EK |
|
Reference Source |
Personal Communication |
|
Scanner Used |
Siemens Plus4 Volume Zoom |
|
KV / mAs / Time per Rotation (sec) |
120 / 165 / .5 |
|
Detector Collimation (mm) |
2.5 |
|
Slice Thickness (mm) |
3 |
|
Data Reconstruction Interval (mm) |
2 |
|
Table Speed (mm per rotation) / Pitch |
15 / 6 |
|
Oral Contrast |
N/A |
|
IV Contrast Volume and Type |
N/A
|
|
Injection Rate |
N/A |
|
Scan Delay (sec) |
N/A |
|
3D Technique Used |
Volume rendering or MPR |
|
Comment: -3D or MPR imaging can be used as an adjunct in select cases. IV contrast may be needed in cases where no stone is detected.
|