MDCT PROTOCOLS

GI

Colon: Focused virtual colonoscopy Printer-ready protocol

Specific Anatomic Region Colon
Application Focused virtual colonoscopy (i.e. stage rectal cancer)
Author Fishman EK
Reference Source Personal Communication
Scanner Used Siemens Plus4 Volume Zoom
KV / mAs / Time per Rotation (sec) 140 / 210 / .5
Detector Collimation (mm) 1
Slice Thickness (mm) 1.25
Data Reconstruction Interval (mm) 1
Table Speed (mm per rotation) / Pitch 6 / 6
Oral Contrast N/A (rectal air only)
IV Contrast Volume and Type 120 cc of Omnipaque 350
Injection Rate 3 cc / sec
Scan Delay (sec) 50 sec
3D Technique Used Volume rendering and MPR

Comments:

  • The pelvis protocol is chosen, which includes a filter to reduce beam hardening artifacts. The rest of the abdomen, including the liver, can be scanned with 5mm collimation.
  • Scan from the pelvis to the diaphragm. This allows the liver to be scanned in the portal phase.