MDCT PROTOCOLS

Chest

Bronchial Tree: Suspected tumor or inflamm. disease Printer-ready protocol

Specific Anatomic Region Bronchial Tree
Application Suspected tumor or inflammatory disease
Author Fishman EK
Reference Source Personal Communication
Scanner Used Siemens Plus4 Volume Zoom
KV / mAs / Time per Rotation (sec) 140 / 100 / .5
Detector Collimation (mm) 1 or 2.5
Slice Thickness (mm) 1.25 or 3
Data Reconstruction Interval (mm) 1-3
Table Speed (mm per rotation) / Pitch 6 / 6 or 15 / 6
Oral Contrast N/A
IV Contrast Volume and Type Either N/A or 120 cc of Omnipaque 350
Injection Rate 2 cc / sec
Scan Delay (sec) 30 sec
3D Technique Used Volume rendering and MPR
Comment:
  • Evaluation of the airways can be done with or without IV contrast, depending on the clinical suspicion. 3D and MPR imaging can better define the pathology in many cases.
  • High resolution algorithm is used in these cases.
  • Varying the rendering parameters creates beautiful virtual images.