VascularPulmonary Artery: R/O pulmonary embolism |
|
Specific Anatomic Region |
Pulmonary Artery |
|
|
Application |
R/O pulmonary embolism |
|
|
Author |
Fishman, E.K. |
|
|
Reference Source |
Personal communication |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
3ml/sec |
|
|
Contrast Volume and Type |
120ml of Omnipaque 350 |
|
|
Area Scanned |
Level of just above aortic arch through lung bases |
|
|
Scan Delay |
25sec |
|
|
Length of Spiral (time) |
30-35sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
5mm/sec |
|
|
Reconstruction Interval |
2mm |
|
|
3D Technique Used |
Volume rendering / MIP/ MPR |
|
|
Comment:
|
||