Vascular
|
|
Specific Anatomic Region |
Abdominal Aorta |
|
|
Application |
Evaluate AAA following stent repair |
|
|
Author |
Dorffner R et al. |
|
|
Reference Source |
J Comput Assist Tomogr 21(3):472-477 |
|
|
Scanner Used |
Siemens Somatom Plus S |
|
|
Injection Rate |
4ml/sec |
|
|
Contrast Volume and Type |
120ml of 300mg/ml nonionic |
|
|
Area Scanned |
From origin of the SMA through the proximal common iliac aa |
|
|
Scan Delay |
25sec |
|
|
Length of Spiral (time) |
32sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
6mm/sec with a pitch of 2 |
|
|
Reconstruction Interval |
1mm |
|
|
3D Technique Used |
MIP |
|
|
Comment: Significant editing of the CT scans was done in order to do the MIP images. The studies were successful in evaluation of the graft, IMA, and renal arteries. |
||
1A![]() |
1B![]() |
Case 1: endovascular stent graft |
2A![]() |
2B![]() |
Case 2: endovascular stent graft with occluded limb |