MusculoskeletalShoulder: Trauma to shoulder joint |
|
Specific Anatomic Region |
Shoulder |
|
|
Application |
Trauma to shoulder joint (includes scapula and humerus) |
|
|
Author |
Fishman EK |
|
|
Reference Source |
Personal communication |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
N/A |
|
|
Contrast Volume and Type |
N/A |
|
|
Area Scanned |
From just above acromioclavicular joint through scapular tip |
|
|
Scan Delay |
None |
|
|
Length of Spiral (time) |
40sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
3-5mm/sec |
|
|
Reconstruction Interval |
2mm |
|
|
3D Technique Used |
Volume rendering and multiplanar obliques |
|
|
Comment: The technique can be modified if only the humeral head is injured. In cases with complex trauma IV contrast may be used to exclude a vascular injury to the mediastinum. The protocol used would use 120ml of contrast injected at 2-3ml/sec with a 30sec delay. |
||