Liver
|
|
Specific Anatomic Region |
Portal Vein |
|
|
Application |
Portal vein patency |
|
|
Author |
Fishman E et al. |
|
|
Reference Source |
Personal communication |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
3cc/sec |
|
|
Contrast Volume and Type |
110-120cc of Omnipaque 350 |
|
|
Area Scanned |
From mid-liver through pancreas |
|
|
Scan Delay |
40sec |
|
|
Length of Spiral (time) |
24-32sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
3-5mm/sec |
|
|
Reconstruction Interval |
1-3mm |
|
|
3D Technique Used |
Volume rendering |
|
|
Comment:
|
||
1A![]() |
1B![]() |
Case 1: normal portal vein |
2A![]() |
2B![]() |
Case 2: portal vein thrombosis |
3A![]() |
3B![]() |
Case 3: cholangiocarcinoma with portal vein thrombosis |
4A![]() |
4B![]() |
Case 4: pseudo-portal vein thrombosis on early phase images |