Liver
|
|
Specific Anatomic Region |
Liver |
|
|
Application |
Differential diagnosis of liver masses |
|
|
Author |
Hoe LV et al. |
|
|
Reference Source |
AJR 1997; 168:1185-1192 |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
2.5-3ml/sec |
|
|
Contrast Volume and Type |
125-150cc of Telebrix (300-380mg/ml) |
|
|
Area Scanned |
Entire liver |
|
|
Scan Delay |
25sec arterial / 80sec venous |
|
|
Length of Spiral (time) |
Approx 30sec |
|
|
Slice Thickness |
5mm |
|
|
Table Speed/Pitch |
Pitch 1-1.5 |
|
|
Reconstruction Interval |
3mm intervals |
|
|
3D Technique Used |
None |
|
|
Comment: Scans in both the arterial and portal vein phases improve the radiologist's ability to differentiate hepatoma and FNH from other tumors is the authors' conclusion. |
||
1A![]() |
1B![]() |
Case 1: hepatoma |
2A![]() |
2B![]() |
Case 2: focal nodular hyperplasia with dual phase imaging. |
3A![]() |
3B![]() |
Case 3: focal nodular hyperplasia. |
4A![]() |
4B![]() |
Case 4: hepatic abscess |
5A![]() |
5B![]() |
Case 5: vascular hepatic sarcoma |