Liver Printer-ready protocol

Evaluate hepatic a. anatomy for liv. transplant

Specific Anatomic Region

Liver

Application

Evaluate hepatic arterial anatomy for liver transplant

Author

Winter TC III et al.

Reference Source

Radiology 1995; 195:363-370

Scanner Used

GE HiSpeed Advantage

Injection Rate

5ml/sec

Contrast Volume and Type

180ml of Omnipaque 300

Area Scanned

Top to bottom of liver

Scan Delay

12sec (approx)

Length of Spiral (time)

30-35sec

Slice Thickness

3mm

Table Speed/Pitch

3-5mm/sec with a pitch of 1:1 to 1:7:1

Reconstruction Interval

1mm

3D Technique Used

MIP and shaded-surface display

Comment: A test bolus of 20ml is injected at 5ml/sec. A single scan is chosen just above the celiac axis. After an 8sec delay, 14 one-second scans are obtained with a one-second interscan delay. In these patients we prefer a dual-phase Spiral CT.

1A 1B Case 1: 3D of varices

2A 2B Case 2: nice hepatic arterial anatomy

3A 3B Case 3: 3D imaging of the hepatic artery
3C

4A 4B Case 4: 3D mapping of liver and portal venous system