KidneyEvaluate as potential renal transplant donor |
|
Specific Anatomic Region |
Kidney |
|
|
Application |
Evaluate a potential renal transplant donor |
|
|
Author |
Smith P, et al |
|
|
Reference Source |
RadioGraphics 1998; 18:589-601 |
|
|
Scanner Used |
Siemens Somatom Plus 4 |
|
|
Injection Rate |
3cc/sec |
|
|
Contrast Volume and Type |
150cc of Omnipaque 350 |
|
|
Area Scanned |
From level of celiac axis to below common iliac aa |
|
|
Scan Delay (2 delays if dual spiral) |
30sec/60-70sec |
|
|
Length of Spiral (time) |
35-40sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
5-6mm/sec or pitch up to 2 |
|
|
Reconstruction Interval |
1mm for arterial phase 2mm for venous phase |
|
|
3D Technique Used |
Volume rendering with MIP in select instances as a complement |
|
|
Comment: The technique is a dual-phase study with the arterial phase for arterial mapping and the venous phase for the renal vein and its variants. A delayed topogram (scoutview) is obtained to evaluate the pelvocalyceal system. |
||