Head and Neck Printer-ready protocol

R/O adenopathy

Specific Anatomic Region

Neck

Application

R/O adenopathy

Author

Fishman EK

Reference Source

Personal Communication

Scanner Used

Siemens Somatom Plus 4

Injection Rate

2-3ml/sec

Contrast Volume and Type

100ml of Omnipaque-350

Area Scanned

Cervical region

Scan Delay

30sec

Length of Spiral (time)

30sec

Slice Thickness

3-5mm

Table Speed/Pitch

5mm/sec

Reconstruction Interval

3-5mm

3D Technique Used

None used

Comment: With Spiral CT this can easily be combined with an examination of the chest. In these cases the question always arises whether to keep the patient's arm by their side or over the head.

1A 1B Case 1: adenopathy due to lymphoma

2A 2B Case 2: SVC and jugular vein thrombosis

3A 3B Case 3: substernal thyroid