GI TractColon: Virtual colonoscopy |
|
Specific Anatomic Region |
Colon |
|
|
Application |
Virtual colonoscopy |
|
|
Author |
Hara AK |
|
|
Reference Source |
AJR 1997; 168:1181-1184 |
|
|
Scanner Used |
GE HiSpeed Advantage |
|
|
Injection Rate |
N/A |
|
|
Contrast Volume and Type |
Rectal air |
|
|
Area Scanned |
Entire abdomen |
|
|
Scan Delay |
None |
|
|
Length of Spiral (time) |
3 to 4 20sec breathhold spirals |
|
|
Slice Thickness |
5mm |
|
|
Table Speed/Pitch |
6.5mm/sec or a pitch of 1.3 |
|
|
Reconstruction Interval |
3mm |
|
|
3D Technique Used |
Shaded surface |
|
|