Chest

Trachea: Virtual bronchoscopy

Specific Anatomic Region

Trachea

Application

Virtual bronchoscopy

Author

Lee KS et al.

Reference Source

RadioGraphics 1977; 17:555-567

Scanner Used

GE HiSpeed Advantage

Injection Rate

N/A

Contrast Volume and Type

None

Area Scanned

Depends on clinical question (i.e. bronchi vs airway)

Scan Delay

None

Length of Spiral (time)

Up to 30sec

Slice Thickness

3mm

Table Speed/Pitch

3mm/sec

Reconstruction Interval

1.5mm

3D Technique Used

Shaded surface

Comment: This technique will have a limited scan distance of 9cm. We believe you can increase the pitch to 2 which gives you 18cm coverage, which is enough for the trachea and major airways. Newer single detector scanners can cover a larger volume and the enrite airway scanned.