Chest
|
|
Specific Anatomic Region |
Bronchial Tree or Airway |
|
|
Application |
Tracheal stenosis |
|
|
Author |
Fishman EK |
|
|
Reference Source |
Personal communication |
|
|
Scanner Used |
Siemens Somatom Plus-4 |
|
|
Injection Rate |
N/A |
|
|
Contrast Volume and Type |
N/A |
|
|
Area Scanned |
From thoracic inlet cephalad to the 2nd or 3rd order bronchi |
|
|
Scan Delay |
None |
|
|
Length of Spiral (time) |
30-40sec |
|
|
Slice Thickness |
3mm |
|
|
Table Speed/Pitch |
3-5mm/sec or a pitch of 1-1.6 |
|
|
Reconstruction Interval |
1-2mm |
|
|
3D Technique Used |
Volume rendering |
|
|
Comment: Use volume rendering with lung isolation algorithm. MPR oblique imaging may also prove helpful. |
||
1A![]() |
1B![]() |
Case 1: 3D virtual bronchoscopy of normal airway |
2A![]() |
2B![]() |
Case 2: tracheal stenosis with virtual imaging |
3A![]() |
3B |
Case 3: tracheal stenosis with 3D virtual bronchoscopy |
3C![]() |
||