Chest Printer-ready protocol

Lung: R/O AVM; eval AVM

Specific Anatomic Region

Lung Mass

Application

R/O AVM; evaluate AVM

Author

Remy J et al.

Reference Source

Radiology 1994; 191:657-664

Scanner Used

Siemens Somatom Plus

Injection Rate

None

Contrast Volume and Type

None

Area Scanned

Several cm above and below the lesion

Scan Delay

None

Length of Spiral (time)

24-36sec

Slice Thickness

2 or 5mm

Table Speed/Pitch

2 or 5mm/sec with a pitch of 1

Reconstruction Interval

1 or 3mm

3D Technique Used

Shaded surface

Comment: An initial spiral scan of the entire chest was done before the focal spiral protocols listed above. This protocol is done without intravenous contrast material. We prefer to use IV contrast in these cases and find that the quality of the 3D image is better. We also will routinely use thin section CT (2.3) as our initial study.

1A 1B Case 1: Pulmonary AVM with 3D rendering
1C 1D

2A 2B Case 2: Pulmonary AVM.
2C